Etc CEM3 v1.5.1 Instrukcja Użytkownika Strona 31

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 76
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 30
2 System Reference 25
Modified Linear (Mod-Linear)
A modified linear curve reduces the voltage change at low control levels for better
performance in low-wattage fixtures.
Square Law (Square)
At low control levels, much of a traditional incandescent fixture’s light output is in the
invisible infrared spectrum. This results in poor visible response to low control levels. A
square law curve applies a multiple derived from the square root of the control level (with
full output equal to 1.00) to increase voltage response at low control levels to compensate
for the infrared loss.
0 20406080100
0
20
40
60
80
100
Control Input (%)
Dimmer Output (%)
0 20406080100
0
20
40
60
80
100
Control Input (%)
Dimmer Output (%)