Sensor
+
Rack (SR+/HSR+ Series)
CEM
+
to CEM3 Retrofit Manual
Revision A
Copyright © 2011 Electronic Theatre Controls, Inc.
All Rights reserved.
Product information and specifications subject to change.
Part Number:
7141M2300
Rev A
Released: September 2011
®
Przeglądanie stron 0
1 2 3 4 5 6 ... 15 16

Podsumowanie treści

Strona 1 - to CEM3 Retrofit Manual

Sensor+ Rack (SR+/HSR+ Series) CEM+ to CEM3 Retrofit ManualRevision ACopyright © 2011 Electronic Theatre Controls, Inc.All Rights reserved.Product inf

Strona 2

8 CEM3 Sensor+ Rack Retrofit ManualStep 5: Make the power and data connections on the backplane.a: Install the dimmer output ribbon cables. Open the b

Strona 3 - Introduction

2 The Retrofit 9Backplane SettingsUpgrade kit backplanes ship from the factory with all DIP switches in the off (down) position. You will have to set

Strona 4 - Overview of this Manual

10 CEM3 Sensor+ Rack Retrofit ManualChange out the AF Cards (if present)If your rack supports Advanced Features (AF) you will need to replace the AF c

Strona 5 - Unpack and Organize

2 The Retrofit 11Finishing TouchesStep 1: Carefully remove old Sensor+ label from the front of the door and discard.Step 2: Clean the door surface to

Strona 6

12 CEM3 Sensor+ Rack Retrofit Manual

Strona 8 - Attach New Power Harness

Corporate Headquarters  3031 Pleasant View Road, P.O. Box 620979, Middleton, Wisconsin 53562-0979 USA  Tel +608 831 4116  Fax +608 836 1736London,

Strona 9 - 2 The Retrofit 7

ETC permits the reproduction of materials in this manual only for non-commercial purposes. All other rights are reserved by ETC.ETC®, and Sensor® are

Strona 10 - CEM3 Ribbon Cable Layout

Introduction 1IntroductionThis manual is intended to guide ETC Service Technicians through the process of upgrading existing Sensor+ rack installation

Strona 11 - 2 The Retrofit 9

2 CEM3 Sensor+ Rack Retrofit ManualSafetyPlease note the following safety warnings before use:• Disconnect power from the racks before all maintenance

Strona 12 - Change out the Beacon PCB

1 Unpack and Organize 3Section 1Unpack and OrganizeThe table below lists the parts and components needed to retrofit a Sensor+ rack (SR+ or HSR+ 6, 12

Strona 13 - Configure the CEM3

4 CEM3 Sensor+ Rack Retrofit Manual

Strona 14

2 The Retrofit 5Section 2The RetrofitPreparationStep 1: Use the Sensor+ Connect web interface to download and save the current configuration out of th

Strona 15

6 CEM3 Sensor+ Rack Retrofit ManualAttach New Power HarnessStep 1: Connect the old power connector to the new power harness adapter found in the kit.

Strona 16

2 The Retrofit 7Make Connections and Install the New BackplaneStep 1: Remove the 3-pin Phoenix connector that ships attached to the rear of the backpl